{"id":17779,"date":"2026-05-08T14:28:17","date_gmt":"2026-05-08T12:28:17","guid":{"rendered":"https:\/\/www.pericoli.com\/?p=17779"},"modified":"2026-05-08T14:34:28","modified_gmt":"2026-05-08T12:34:28","slug":"erp-2026","status":"publish","type":"post","link":"https:\/\/www.pericoli.com\/en\/erp-2026\/","title":{"rendered":"ErP 2026 and Agricultural Ventilation: What Changes and How to Stay Compliant"},"content":{"rendered":"<h2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\">What is EU Regulation 2024\/1834 \u2014 and why does it matter for agriculture?<\/h2>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">From <strong>24 July 2026<\/strong>, a new European regulation will change the rules for industrial fans across all sectors, including agricultural ventilation. EU Regulation 2024\/1834, known in the industry as <strong>ErP 2026<\/strong>, replaces the previous Fan Regulation (EU) 327\/2011 and introduces significantly stricter requirements for fan efficiency, product information, and spare parts availability.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">For anyone involved in designing, installing, or purchasing ventilation systems for poultry houses, livestock facilities, or greenhouses, understanding these changes is no longer optional. Every fan placed on the EU market from that date forward must comply.<\/p>\n<h2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\">What ErP 2026 actually requires<\/h2>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The regulation covers three main areas:<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">1. Higher energy efficiency standards<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">ErP 2026 raises the minimum efficiency thresholds that were first introduced in 2013 and tightened in 2015. The new limits apply to all <strong>axial, centrifugal, cross-flow, mixed-flow, and jet-flow fans<\/strong> with an electric input power between <strong>125W and 500kW<\/strong> \u2014 whether sold standalone or integrated into larger products such as ventilation units or climate control systems.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The regulation evaluates the fan as a complete functional system: impeller, motor, and stator together. This is a significant shift from previous versions, which placed more focus on individual components.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">2. Expanded product information requirements<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">From July 2026, every compliant fan must carry clearly accessible information including:<\/p>\n<ul class=\"[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"whitespace-normal break-words pl-2\">Model identifier and manufacturer details<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Energy efficiency values (at full and partial load)<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Year of manufacture<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Instructions for repair, disassembly, and recycling at end of life<\/li>\n<\/ul>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">This information must appear on the product label, in the technical manual, and on the manufacturer&#8217;s website and catalogues.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">3. Spare parts availability<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Manufacturers must guarantee the availability of critical spare parts (motors, bearings, belts, and propellers) for <strong>at least 10 years<\/strong> after the last unit of a model is sold. Maximum delivery time for spare parts is <strong>6 weeks<\/strong>.<\/p>\n<h2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\">Who is responsible for compliance?<\/h2>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">This is one of the most practical questions in the supply chain. According to the regulation, <strong>responsibility lies with whoever completes the fan and places it on the EU market<\/strong> \u2014 even if the fan is part of a larger system.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">This means:<\/p>\n<ul class=\"[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"whitespace-normal break-words pl-2\"><strong>Manufacturers<\/strong> who supply complete fan assemblies (impeller + motor + stator) are responsible for their products&#8217; compliance and documentation.<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Importers and authorised representatives<\/strong> placing fans on the EU market for the first time share that responsibility and must ensure that manufacturers provide all required performance data.<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Dealers<\/strong> who hold stock invoiced before 24 July 2026 can continue selling those units in the EU without restriction.<\/li>\n<\/ul>\n<h2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\">Impact on agricultural applications<\/h2>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">Poultry and livestock ventilation<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Agricultural ventilation operates under demanding conditions: continuous duty cycles, variable pressure environments, corrosion exposure. ErP 2026 pushes manufacturers to optimise fan systems at real operating points, not just laboratory benchmarks. For integrators and farm operators, this means evaluating not only airflow capacity but the <strong>efficiency curve across the full operating range<\/strong>.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">Embedded fans: a specific timeline<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Fans integrated into larger systems, such as ventilation units or climate control equipment, benefit from a <strong>transitional period until 24 July 2027<\/strong>, giving manufacturers of those systems additional time to adapt. After that date, the full ErP 2026 requirements apply.<\/p>\n<h3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\">What about existing installations?<\/h3>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">ErP 2026 applies to fans <strong>placed on the market<\/strong>, not to systems already in operation. Retrofitting existing installed fans is not mandatory. However, spare part fans used to replace fans in existing systems can be sold as non-compliant until <strong>23 July 2037<\/strong>, provided they carry the appropriate labelling.<\/p>\n<h2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\">Key dates to know<\/h2>\n<div class=\"overflow-x-auto w-full px-2 mb-6\">\n<table class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\">\n<thead class=\"text-left\">\n<tr>\n<th class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\">Date<\/th>\n<th class=\"text-text-100 border-b-0.5 border-border-300\/60 py-2 pr-4 align-top font-bold\" scope=\"col\">What happens<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"><strong>24 July 2026<\/strong><\/td>\n<td class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\">ErP 2026 applies. Only compliant fans can be placed on the EU market. Labelling, manuals, and online product info must comply.<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"><strong>24 July 2027<\/strong><\/td>\n<td class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\">Compliance deadline for fans integrated into other products. Partial load performance curve requirements apply.<\/td>\n<\/tr>\n<tr>\n<td class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\"><strong>23 July 2037<\/strong><\/td>\n<td class=\"border-b-0.5 border-border-300\/30 py-2 pr-4 align-top\">Non-compliant spare part fans completely banned from the EU market.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\">Pericoli product range: ready for ErP 2026<\/h2>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">At Termotecnica Pericoli, compliance with EU ecodesign requirements is not a new challenge. Our engineering teams have been working on the ErP 2026 transition for an extended period, with a focus on maintaining the performance our customers depend on while meeting the new efficiency requirements.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">The Pericoli ErP 2026 product range &#8211; covering the <strong>EOD<\/strong>, <strong>EOC<\/strong>, <strong>EOR\/EOS\/EWS<\/strong>, and <strong>EWD\/ERD<\/strong> families- will be available from <strong>1 October 2026<\/strong>. Several models in our range already meet the new standards without modification.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">Key principles behind our updated range:<\/p>\n<ul class=\"[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"whitespace-normal break-words pl-2\"><strong>Efficiency improvements without performance compromise<\/strong> \u2014 updated propeller designs and motor configurations optimised for real operating conditions in agricultural environments<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Continuity of spare parts supply<\/strong> \u2014 we are committed to the 10-year availability requirement across all compliant models<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Transparent technical documentation<\/strong> \u2014 performance data, efficiency values, and labelling updated in compliance with the regulation<\/li>\n<\/ul>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">For specific product information or to plan your orders around the transition, contact our team at <strong><a class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"mailto:pit@pericoli.com\">pit@pericoli.com<\/a><\/strong> or speak with your dedicated Pericoli sales representative.<\/p>\n<h2 class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\">Summary: what to do now<\/h2>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\">If you are a distributor, integrator, or purchasing manager working with agricultural ventilation in the EU:<\/p>\n<ol class=\"[li_&amp;]:mb-0 [li_&amp;]:mt-1 [li_&amp;]:gap-1 [&amp;:not(:last-child)_ul]:pb-1 [&amp;:not(:last-child)_ol]:pb-1 list-decimal flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"whitespace-normal break-words pl-2\"><strong>Audit your current stock<\/strong> \u2014 identify which models are already ErP 2026 compliant and which are not.<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Review orders planned for Q3 2026<\/strong> \u2014 plan deliveries to avoid the transition window where ErP 2026 applies but updated products are not yet available.<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Speak to your supplier<\/strong> \u2014 manufacturers should be able to give you a clear picture of their compliant product range and availability timeline.<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Check documentation<\/strong> \u2014 from 24 July 2026, any fan placed on the EU market must carry the required labels and technical information.<\/li>\n<\/ol>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"><em>For more information about the Pericoli ErP 2026 product range, contact <a class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"mailto:pit@pericoli.com\">pit@pericoli.com<\/a><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>What is EU Regulation 2024\/1834 \u2014 and why does it matter for agriculture? From 24 July 2026, a new European regulation will change the rules for industrial fans across all sectors, including agricultural ventilation. EU Regulation 2024\/1834, known in the industry as ErP 2026, replaces the previous Fan Regulation (EU) 327\/2011 and introduces significantly stricter [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":17777,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[68,18],"tags":[],"class_list":["post-17779","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ventilation-systems","category-news-termotecnica-pericoli"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ErP 2026 Agricultural Fans: EU Regulation 2024\/1834 Explained<\/title>\n<meta name=\"description\" content=\"EU Regulation 2024\/1834 (ErP 2026) sets new ecodesign standards for industrial fans from July 2026. Find out what changes for agricultural ventilation...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.pericoli.com\/en\/erp-2026\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ErP 2026 Agricultural Fans: EU Regulation 2024\/1834 Explained\" \/>\n<meta property=\"og:description\" content=\"EU Regulation 2024\/1834 (ErP 2026) sets new ecodesign standards for industrial fans from July 2026. Find out what changes for agricultural ventilation...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.pericoli.com\/en\/erp-2026\/\" \/>\n<meta property=\"og:site_name\" content=\"Termotecnica Pericoli\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-08T12:28:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-08T12:34:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.pericoli.com\/wp-content\/uploads\/2026\/05\/ERP2026.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Termotecnica\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Termotecnica\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ErP 2026 Agricultural Fans: EU Regulation 2024\/1834 Explained","description":"EU Regulation 2024\/1834 (ErP 2026) sets new ecodesign standards for industrial fans from July 2026. Find out what changes for agricultural ventilation...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.pericoli.com\/en\/erp-2026\/","og_locale":"en_US","og_type":"article","og_title":"ErP 2026 Agricultural Fans: EU Regulation 2024\/1834 Explained","og_description":"EU Regulation 2024\/1834 (ErP 2026) sets new ecodesign standards for industrial fans from July 2026. Find out what changes for agricultural ventilation...","og_url":"https:\/\/www.pericoli.com\/en\/erp-2026\/","og_site_name":"Termotecnica Pericoli","article_published_time":"2026-05-08T12:28:17+00:00","article_modified_time":"2026-05-08T12:34:28+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/www.pericoli.com\/wp-content\/uploads\/2026\/05\/ERP2026.webp","type":"image\/webp"}],"author":"Termotecnica","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Termotecnica","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/#article","isPartOf":{"@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/"},"author":{"name":"Termotecnica","@id":"https:\/\/www.pericoli.com\/en\/#\/schema\/person\/87a70c4c60a1cb718315b355a07fcc55"},"headline":"ErP 2026 and Agricultural Ventilation: What Changes and How to Stay Compliant","datePublished":"2026-05-08T12:28:17+00:00","dateModified":"2026-05-08T12:34:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/"},"wordCount":892,"commentCount":0,"publisher":{"@id":"https:\/\/www.pericoli.com\/en\/#organization"},"image":{"@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pericoli.com\/wp-content\/uploads\/2026\/05\/ERP2026.webp","articleSection":["All about ventilation systems","News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.pericoli.com\/en\/erp-2026\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/","url":"https:\/\/www.pericoli.com\/en\/erp-2026\/","name":"ErP 2026 Agricultural Fans: EU Regulation 2024\/1834 Explained","isPartOf":{"@id":"https:\/\/www.pericoli.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/#primaryimage"},"image":{"@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/#primaryimage"},"thumbnailUrl":"https:\/\/www.pericoli.com\/wp-content\/uploads\/2026\/05\/ERP2026.webp","datePublished":"2026-05-08T12:28:17+00:00","dateModified":"2026-05-08T12:34:28+00:00","description":"EU Regulation 2024\/1834 (ErP 2026) sets new ecodesign standards for industrial fans from July 2026. Find out what changes for agricultural ventilation...","breadcrumb":{"@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.pericoli.com\/en\/erp-2026\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/#primaryimage","url":"https:\/\/www.pericoli.com\/wp-content\/uploads\/2026\/05\/ERP2026.webp","contentUrl":"https:\/\/www.pericoli.com\/wp-content\/uploads\/2026\/05\/ERP2026.webp","width":1920,"height":1080,"caption":"Erp2026-termotecnica pericoli"},{"@type":"BreadcrumbList","@id":"https:\/\/www.pericoli.com\/en\/erp-2026\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.pericoli.com\/en\/"},{"@type":"ListItem","position":2,"name":"News","item":"https:\/\/www.pericoli.com\/en\/news-termotecnica-pericoli\/"},{"@type":"ListItem","position":3,"name":"All about ventilation systems","item":"https:\/\/www.pericoli.com\/en\/news-termotecnica-pericoli\/ventilation-systems\/"},{"@type":"ListItem","position":4,"name":"ErP 2026 and Agricultural Ventilation: What Changes and How to Stay Compliant"}]},{"@type":"WebSite","@id":"https:\/\/www.pericoli.com\/en\/#website","url":"https:\/\/www.pericoli.com\/en\/","name":"Termotecnica Pericoli","description":"","publisher":{"@id":"https:\/\/www.pericoli.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.pericoli.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.pericoli.com\/en\/#organization","name":"Termotecnica Pericoli","url":"https:\/\/www.pericoli.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.pericoli.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.pericoli.com\/wp-content\/uploads\/2022\/02\/Risorsa2logo.svg","contentUrl":"https:\/\/www.pericoli.com\/wp-content\/uploads\/2022\/02\/Risorsa2logo.svg","caption":"Termotecnica Pericoli"},"image":{"@id":"https:\/\/www.pericoli.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.pericoli.com\/en\/#\/schema\/person\/87a70c4c60a1cb718315b355a07fcc55","name":"Termotecnica","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/f770a79adbfafb07b4a3ae99644c5e8e505e3636c5eabd9af15c32bd185c8569?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f770a79adbfafb07b4a3ae99644c5e8e505e3636c5eabd9af15c32bd185c8569?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f770a79adbfafb07b4a3ae99644c5e8e505e3636c5eabd9af15c32bd185c8569?s=96&d=mm&r=g","caption":"Termotecnica"},"url":"https:\/\/www.pericoli.com\/en\/author\/termotecnica\/"}]}},"_links":{"self":[{"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/posts\/17779","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/comments?post=17779"}],"version-history":[{"count":1,"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/posts\/17779\/revisions"}],"predecessor-version":[{"id":17780,"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/posts\/17779\/revisions\/17780"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/media\/17777"}],"wp:attachment":[{"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/media?parent=17779"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/categories?post=17779"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pericoli.com\/en\/wp-json\/wp\/v2\/tags?post=17779"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}